{"id":12594,"date":"2024-10-20T02:12:20","date_gmt":"2024-10-20T00:12:20","guid":{"rendered":"https:\/\/collectif-accad.fr\/site\/?p=12594"},"modified":"2024-10-15T07:14:39","modified_gmt":"2024-10-15T05:14:39","slug":"implants-cardiaques-et-champs-electromagnetiques-artificiels","status":"publish","type":"post","link":"https:\/\/collectif-accad.fr\/site\/implants-cardiaques-et-champs-electromagnetiques-artificiels\/","title":{"rendered":"Implants cardiaques et Champs \u00c9lectroMagn\u00e9tiques artificiels"},"content":{"rendered":"<p style=\"text-align: justify;\"><span style=\"font-family: Comic Sans MS, cursive;\"><span style=\"font-size: medium;\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-12579 aligncenter\" src=\"https:\/\/collectif-accad.fr\/site\/wp-content\/uploads\/2024\/10\/Affiche-Verte-2411-01.jpg\" alt=\"\" width=\"417\" height=\"590\" srcset=\"https:\/\/collectif-accad.fr\/site\/wp-content\/uploads\/2024\/10\/Affiche-Verte-2411-01.jpg 800w, https:\/\/collectif-accad.fr\/site\/wp-content\/uploads\/2024\/10\/Affiche-Verte-2411-01-212x300.jpg 212w, https:\/\/collectif-accad.fr\/site\/wp-content\/uploads\/2024\/10\/Affiche-Verte-2411-01-724x1024.jpg 724w, https:\/\/collectif-accad.fr\/site\/wp-content\/uploads\/2024\/10\/Affiche-Verte-2411-01-768x1087.jpg 768w\" sizes=\"auto, (max-width: 417px) 100vw, 417px\" \/><\/span><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-size: 18pt;\"><strong><span style=\"font-family: Comic Sans MS, cursive;\">Principe d\u2019un implant cardiaque<\/span><\/strong><\/span><\/p>\n<p><!--more--><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-family: Comic Sans MS, cursive;\"><span style=\"font-size: medium;\">Le stimulateur cardiaque est un implant m\u00e9dical actif. Il est constitu\u00e9 d\u2019un bo\u00eetier \u00e9tanche en titane plac\u00e9 en sous-cutan\u00e9 dans la r\u00e9gion pectorale ou quelquefois abdominale. Il est muni d\u2019une ou deux sondes (comprenant une ou deux \u00e9lectrodes) dont l\u2019extr\u00e9mit\u00e9 est amen\u00e9e dans le ventricule droit et\/ou l\u2019oreillette droite par le syst\u00e8me veineux. Le bo\u00eetier contient une pile au lithium dont la dur\u00e9e de vie d\u2019une dizaine d\u2019ann\u00e9es permet de laisser une certaine autonomie. Un circuit \u00e9lectronique hybride d\u00e9coupe le courant fourni par la pile en impulsions d\u2019une dur\u00e9e inf\u00e9rieure \u00e0 1 ms et d\u2019une amplitude de quelques volts.<\/span><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-family: Comic Sans MS, cursive;\"><span style=\"font-size: medium;\">Ils peuvent \u00eatre pourvus d\u2019une \u00e9lectronique tr\u00e8s sophistiqu\u00e9e, stimulant de fa\u00e7on programm\u00e9e une ou plusieurs cavit\u00e9s cardiaques selon une chronologie respectant le plus possible la r\u00e9alit\u00e9 physiologique. La programmation de ces appareils est modifiable par application d\u2019un champ magn\u00e9tique transcutan\u00e9 en cas d\u2019\u00e9volution de la maladie.<\/span><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-family: Comic Sans MS, cursive;\"><span style=\"font-size: medium;\">Le dispositif est g\u00e9n\u00e9ralement \u00e9quip\u00e9 d&rsquo;une antenne radio-fr\u00e9quence permettant la communication de donn\u00e9es \u00e0 travers la peau vers un dispositif externe (souvent par GSM 2G jusqu\u2019\u00e0 un serveur central h\u00e9bergeur de donn\u00e9es).<\/span><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-family: Comic Sans MS, cursive;\"><span style=\"font-size: medium;\">Perturbations d\u2019origine \u00e9lectromagn\u00e9tique<\/span><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-family: Comic Sans MS, cursive;\"><span style=\"font-size: medium;\">Les interf\u00e9rences \u00e9lectromagn\u00e9tiques, sont constitu\u00e9es par un signal \u00e9lectrique d\u2019origine non cardiaque qui entra\u00eene des modifications dans le fonctionnement des circuits de d\u00e9tection ou de stimulation des stimulateurs cardiaques. Les courants induits par les perturbations \u00e9lectromagn\u00e9tiques rayonn\u00e9es ou les ph\u00e9nom\u00e8nes de d\u00e9charges \u00e9lectrostatiques sont susceptibles d\u2019engendrer des interf\u00e9rences.<\/span><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-family: Comic Sans MS, cursive;\"><span style=\"font-size: medium;\">Les ondes \u00e9lectromagn\u00e9tiques peuvent \u00eatre sources de perturbations apr\u00e8s avoir suivi deux types de cheminement. Ces ondes, soit parce qu\u2019elles \u00ab miment \u00bb les signaux cardiaques et leurrent alors le syst\u00e8me de d\u00e9tection (en particulier dans le cas du d\u00e9fibrillateur), soit parce qu\u2019elles sont de fortes \u00e9nergies et sont incompl\u00e8tement filtr\u00e9es, peuvent induire un courant dans la sonde et ne pas \u00eatre filtr\u00e9es \u00e0 l\u2019entr\u00e9e du bo\u00eetier.<\/span><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-family: Comic Sans MS, cursive;\"><span style=\"font-size: medium;\">En outre, lorsqu\u2019elles correspondent \u00e0 des champs magn\u00e9tiques statiques ou des ondes \u00e9lectromagn\u00e9tiques de tr\u00e8s hautes fr\u00e9quences, elles sont capables de p\u00e9n\u00e9trer dans le bo\u00eetier sans transiter par la sonde \u00e9vitant ainsi les filtres d\u2019entr\u00e9e.<\/span><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-family: Comic Sans MS, cursive;\"><span style=\"font-size: medium;\">Le risque de perturbation \u00e9lectromagn\u00e9tique d\u00e9pend de plusieurs param\u00e8tres, qui sont principalement les valeurs de la fr\u00e9quence et de l\u2019intensit\u00e9 du rayonnement \u00e9mis.<\/span><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-family: Comic Sans MS, cursive;\"><span style=\"font-size: medium;\">Les pr\u00e9cautions \u00e0 prendre<\/span><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-family: Comic Sans MS, cursive;\"><span style=\"font-size: medium;\">Parmi les pr\u00e9cautions \u00e0 prendre, nous ne traiterons ici que celles li\u00e9es aux interf\u00e9rences \u00e9lectromagn\u00e9tiques.<\/span><\/span><\/p>\n<p style=\"text-align: justify;\">\u2022 <span style=\"font-family: Comic Sans MS, cursive;\"><span style=\"font-size: medium;\">Veillez \u00e0 toujours avoir sur vous votre carte de porteur de stimulateur cardiaque !<\/span><\/span><\/p>\n<p style=\"text-align: justify;\">\u2022 <span style=\"font-family: Comic Sans MS, cursive;\"><span style=\"font-size: medium;\">Lorsque vous devez passer dans un portique de d\u00e9tection, pr\u00e9sentez votre carte de porteur d&rsquo;un stimulateur, le passage vous sera \u00e9pargn\u00e9. Le risque d\u2019une perturbation est minime, mais il est toujours possible que cela d\u00e9clenche les alarmes et surtout que cela d\u00e9r\u00e8gle les param\u00e8tres du stimulateur cardiaque.<\/span><\/span><\/p>\n<p style=\"text-align: justify;\">\u2022 <span style=\"font-family: Comic Sans MS, cursive;\"><span style=\"font-size: medium;\">De m\u00eame, il est conseill\u00e9 d&rsquo;\u00e9viter la proximit\u00e9 des plaques de chauffage \u00e0 induction, ou la pratique de la soudure \u00e0 l\u2019arc.<\/span><\/span><\/p>\n<p style=\"text-align: justify;\">\u2022 <span style=\"font-family: Comic Sans MS, cursive;\"><span style=\"font-size: medium;\">Il est, de m\u00eame, pr\u00e9f\u00e9rable de tenir son t\u00e9l\u00e9phone portable \u00e0 distance du pacemaker. Les ondes sont interpr\u00e9t\u00e9es comme des signaux externes.<\/span><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-family: Comic Sans MS, cursive;\"><span style=\"font-size: medium;\">Les pacemakers peuvent interpr\u00e9ter par erreur les interf\u00e9rences \u00e9lectromagn\u00e9tiques (IEM) des smartphones comme un signal cardiaque, ce qui peut causer un arr\u00eat bref du dispositif pouvant entra\u00eener des pauses dans le rythme cardiaque, voire des syncopes.<\/span><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-family: Comic Sans MS, cursive;\"><span style=\"font-size: medium;\"><a href=\"https:\/\/www.medtronic.com\/ca-fr\/votre-sante\/guide-electromagnetique\/foire-aux-questions.html\">https:\/\/www.medtronic.com\/ca-fr\/votre-<\/a><\/span><\/span><\/p>\n<p style=\"text-align: justify;\">\u2022 <span style=\"font-family: Comic Sans MS, cursive;\"><span style=\"font-size: medium;\">D\u2019apr\u00e8s l\u2019ANSES (\u00e9tude de 2016 sur les dispositifs m\u00e9dicaux et la compatibilit\u00e9 \u00e9lectromagn\u00e9tique), m\u00eame les puces RFID peuvent influer sur le fonctionnement des dispositifs m\u00e9dicaux, \u00e0 des distances inf\u00e9rieures \u00e0 1 m environ pour les syst\u00e8mes test\u00e9s. Ces r\u00e9sultats sont en accord avec les observations r\u00e9alis\u00e9es sur les syst\u00e8mes utilisant des fr\u00e9quences et des puissances voisines de celles utilis\u00e9es par les RFID.<\/span><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-family: Comic Sans MS, cursive;\"><span style=\"font-size: medium;\"><a href=\"https:\/\/www.anses.fr\/fr\/system\/files\/AP2011SA0211Ra.pdf\">https:\/\/www.anses.fr\/fr\/system\/files\/AP<\/a> <\/span><\/span><\/p>\n<p style=\"text-align: justify;\">\u2022 <span style=\"font-family: Comic Sans MS, cursive;\"><span style=\"font-size: medium;\">Il est aussi constat\u00e9 que vis \u00e0 vis de la t\u00e9l\u00e9phonie mobile, le risque est plus important pour les valeurs inf\u00e9rieures de la fr\u00e9quence d\u2019\u00e9mission utilis\u00e9e par les op\u00e9rateurs, soit entre 700 et 900 MHz. Cette gamme de fr\u00e9quence se retrouve parmi les fr\u00e9quences des 2, 3, 4G, mais aussi de la 5G bas d\u00e9bit \u00e0 700 MHz.<\/span><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-family: Comic Sans MS, cursive;\"><span style=\"font-size: medium;\">Ainsi, habiter \u00e0 proximit\u00e9 d\u2019antennes relais, ou dans un immeuble sur le toit duquel une antenne est install\u00e9e, n\u2019est gu\u00e8re compatible avec un implant m\u00e9dical.<\/span><\/span><\/p>\n<p style=\"text-align: justify;\">\u2022 <span style=\"font-family: Comic Sans MS, cursive;\"><span style=\"font-size: medium;\">Concernant le courant alternatif 50 Hz, avec les stimulateurs actuels, r\u00e9gl\u00e9s en mode bipolaire et une sensibilit\u00e9 ventriculaire courante (2mV en g\u00e9n\u00e9ral), le risque d\u2019interf\u00e9rence est quasi inexistant pour les expositions rencontr\u00e9es dans la vie de tous les jours. Il est n\u00e9anmoins recommand\u00e9 de ne pas utiliser de petits moteurs (type appareil de bricolage, perceuse) \u00e0 proximit\u00e9 imm\u00e9diate du bo\u00eetier du stimulateur.<\/span><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-family: Comic Sans MS, cursive;\"><span style=\"font-size: medium;\"><a href=\"https:\/\/ursi-france.telecom-paristech.fr\/fileadmin\/journees_scient\/docs_journees_2012\/data\/articles\/000018.pdf\">https:\/\/ursi-france.telecom-paristec<\/a> <\/span><\/span><\/p>\n<p style=\"text-align: justify;\">\u2022 <span style=\"font-family: Comic Sans MS, cursive;\"><span style=\"font-size: medium;\">Toutefois, lorsque le Courant Porteur en Ligne Linky est activ\u00e9 et circule dans le r\u00e9seau \u00e9lectrique Basse Tension local (donc dans tous les logements, qu\u2019ils soient \u00e9quip\u00e9s ou non d\u2019un compteur Linky), il convient d\u2019appliquer un principe de pr\u00e9caution puisqu\u2019il s\u2019agit de fr\u00e9quences plus \u00e9lev\u00e9es, comprises entre 35 et 91 kHz.<\/span><\/span><\/p>\n<p style=\"text-align: justify;\"><a href=\"https:\/\/www.jle.com\/download\/ers-307042-31598-risque_dinterference_entre_les_implants_medicaux_et_les_champs_electromagnetiques_basses_frequences-a.pdf\"><span style=\"font-family: Comic Sans MS, cursive;\"><span style=\"font-size: medium;\">https:\/\/www.jle.com\/download\/ers-307042-31598-risque_dint<\/span><\/span><\/a><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-family: Comic Sans MS, cursive;\"><span style=\"font-size: medium;\"><a href=\"https:\/\/www.robindestoits.org\/attachment\/2012549\/\">https:\/\/www.robindestoits.org\/attachment\/2012549\/<\/a> <\/span><\/span><\/p>\n<p style=\"text-align: center;\"><span style=\"font-family: Comic Sans MS, cursive;\"><span style=\"font-size: medium;\">** **<\/span><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-family: Comic Sans MS, cursive;\"><span style=\"font-size: medium;\">Autres documents<br \/>\n<\/span><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #c9211e;\"><span style=\"font-family: Comic Sans MS, cursive;\"><span style=\"font-size: medium;\">Effets-du-compteur-LINKY-sur-la-sante-humaine-a-l-attention-du-corps-medical.pdf<\/span><\/span><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-family: Comic Sans MS, cursive;\"><span style=\"font-size: medium;\">\u00a0<\/span><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-family: Comic Sans MS, cursive;\"><span style=\"font-size: medium;\"><a href=\"https:\/\/reporterre.net\/Linky-le-compteur-qui-va-augmenter-notre-exposition-aux-ondes-electro\">https:\/\/reporterre.net\/Linky-le-compteur-qui-va-au<\/a> <\/span><\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Principe d\u2019un implant cardiaque<\/p>\n","protected":false},"author":4,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-12594","post","type-post","status-publish","format-standard","hentry","category-non-classe"],"_links":{"self":[{"href":"https:\/\/collectif-accad.fr\/site\/wp-json\/wp\/v2\/posts\/12594","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/collectif-accad.fr\/site\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/collectif-accad.fr\/site\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/collectif-accad.fr\/site\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/collectif-accad.fr\/site\/wp-json\/wp\/v2\/comments?post=12594"}],"version-history":[{"count":1,"href":"https:\/\/collectif-accad.fr\/site\/wp-json\/wp\/v2\/posts\/12594\/revisions"}],"predecessor-version":[{"id":12595,"href":"https:\/\/collectif-accad.fr\/site\/wp-json\/wp\/v2\/posts\/12594\/revisions\/12595"}],"wp:attachment":[{"href":"https:\/\/collectif-accad.fr\/site\/wp-json\/wp\/v2\/media?parent=12594"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/collectif-accad.fr\/site\/wp-json\/wp\/v2\/categories?post=12594"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/collectif-accad.fr\/site\/wp-json\/wp\/v2\/tags?post=12594"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}